Maintenance Commands
555-233-143
7-182 Issue 1 May 2002
Output
The following example shows the output from the list measurements ethernet
command.
Field Descriptions
Date
The date that the data was collected.
Time
The current 15-minute interval in which the action was performed
CRC Check
The error count for CRC errors
Total
The total value of the counter on the board
NOTE:
The counter value can be up to 11 digits long because of the 32-bit
counter on the board. After the occurrence of an “N/A,” the delta
equals the total. Busying out or releasing a board or a port, using the
reset board command, and reseating the board all clear the firmware
counters.
Delta
The difference between the current and the previous sample
Collision
Count
The error count for collisions on the ethernet
list measurements clan ethernet 1C1017 Page 1 of x
Switch Name: sierra Date:4:07pm MON AUG 01,1999
C-LAN ETHERNET PERFORMANCE MEASUREMENT DETAILED REPORT
Date Time CRC Check Collision Count
total delta total delta
08/01 0308 650 50 650 250
08/01 0253 600 600 400 400
08/01 0238 N/A N/A N/A N/A
08/01 0223 1000000570 20 10000000570 20
08/01 0208 1000000550 10000000550 10000000550 10000000550