Maintenance Commands
555-233-143
7-184 Issue 1 May 2002
Output
The following example shows the output from the list measurements clan ppp
command.
Field Descriptions
Date
The date that the data was collected
Time
The current 15-minute interval in which the action was performed
CRC Check
The error count for CRC errors
Total
Total value of the board counter.
NOTE:
The counter value can be up to 7 digits long because the 16- bit
counter on the board. After the occurrence of an “N/A” the delta
equals the total. Busying out or releasing a board or a port, using the
reset board command, and reseating the board all clear the firmware
counters.
Delta
The difference between the current and the previous sample
Invalid Frame
The number of invalid frames detected. Invalid frames are the frames that
are misaligned.
CHAP Failures
The number of failed attempts for ppp authentication
list measurements clan ppp 1C1001 Page 1 of x
Switch Name: sierra Date:02/02/1999
C-LAN PPP PERFORMANCE MEASUREMENT DETAILED REPORT
Date Time CRC Check Invalid Frame CHAP Failures
Total Delta Total Delta Total ‘Delta
02/01 03:08 85 25 185 85 5 0
02/01 02:53 60 60 100 100 5 5
02/01 02:38 N/A N/A N/A N/A N/A N/A
02/01 02:23 1000060 10 1000090 10 25 5
02/01 02:08 1000050 1000050 1000080 1000080 20 20