PNC Cabling — Fiber Hardware
Issue 1 May 2002
2-7555-233-143
Figure 2-2. Typical DS1 CONV Connections to Remote EPNs
1. Place duplicate pairs in different carriers.
2. When removing two or more, the maximum cable distance between any
two remoted endpoints is 100 miles (161 km). For example, if one EPN is
75 miles (121 km) from the switch node cabinet, then no other EPN can be
more than 25 miles (40.2 km) from the same switch node cabinet.
3. Use a 846447637 within a carrier for a TN574, use a 847245750 within a
carrier for a TN1654.
Use a 846448645 within a cabinet between carriers for a TN574, use a
847245768 within a cabinet between carriers for TN1654.
Switch
Switch
Switch Switch
Switch
TN570
circuit
pack
TN570
circuit
pack
TN570
circuit
pack
TN570
circuit
pack
TN573
circuit
pack
TN574
circuit
pack
TN574
circuit
pack
TN574
circuit
pack
TN573
circuit
pack
TN574
circuit
pack
TN573
circuit
pack
TN574
circuit
pack
TN574
circuit
pack
846448637
or
846448645
846448637
or
846448645
H600-348, G-( ) H600-348, G-( )
CSU
CSU
CSU
CSU
CSU
CSU
Cross
connect
field
Cross
connect
field
Cross
connect
field
846448637
DS1C
Fully duplicated
EPN
EPN
9823A
9823A
9823A
9823A
For direct
cross connect,
see text.
For direct
cross connect,
see text.
100 miles
100 miles
650 feet 650 feet
maximum
650 feet650 feet
FL2P-XX
846448652
H600-348, G-( )
H600-348, G-( )
846448637
cydfep31 KLC 032001