status pnc
Issue 1 May 2002
7-373555-233-143
Field Descriptions
Table 7-53. Fault Class Field Descriptions
Fault Class Priority Description MOs
FC_EAL 1 Number of PNs with EALs down EXP-PN
FC_INL 2 Number of PNs with LINL, RINL, or EI-SNI neighbor
link faults
EXP-PN
SN-CONF
FC_HW 3 Number of PNs affected by hardware faults in a link
having an EI as an endpoint (Endpoints can be
determined with list fiber-link.)
EXP-INTF
SN-CONF
FIBER-LK
SNI-BD
DS1C-BD
FC_PER 4 Number of PNs affected by SNI peer link faults for
SNIs connected to EIs
SNI-PEER
FC_DS1 5 Number of PNs affected by DS1C facility faults DS1FAC
FC_SNIL 6 Number of inter-switch-node fibers affected by peer
or neighbor link faults
SNI-PEER
FC_SNIHW 7 Number of inter-switch-node fibers affected by
hardware faults
SN-CONF
SNI-BD
FIBER-LK
Major Alarms,
Minor Alarms,
Warning Alarms
The number of major, minor, or warning alarms logged against
DS1C-BD, SNI-BD, SNC-BD, EXP-INTF, FIBER-LK, DS1C-FAC,
SNC-LINK, SN-CONF, SNC-REF, SYNCH, and SNI-PEER on the
indicated PNC.
Switch Node
Locations
The locations of all Switch Nodes comprising the indicated PNC.

Table of Contents