status trunk
Issue 1 May 2002
7-401555-233-143
Output
The following screen shows typical results for an S8700 IP Connect system.
For an ip-TDM call, the Audio Switch Port field shows one of ports 1-8 on a
TN2302 Prowler board.
status trunk 20/1
TRUNK STATUS
Trunk Group/Member: 0020/001 Service State: in-service/idle
Port: T00016 Maintenance Busy? no
Signaling Group ID: CA-TSC state: none
Connected Ports:
Port Near-end IP Addr : Port Far-end IP Addr : Port
Q.931: 08A0617 192.168. 18. 41 : 10071 172. 17. 17.107 : 7020
H.245:
Audio:
H.245 Tunneled in Q.931? no
Audio Connection Type: ip-tdm
status trunk 1/19
TRUNK STATUS
Trunk Group/Member: 01/19 Service State: in-service/active
Port: T00123 Maintenance Busy? no
Signaling Group ID: 1 CA-TSC state: not allowed
MM Conference ID: 8
MM Endpoint ID: 2
Connected Ports: S00004
Switch IP IP
Port Near-end IP Addr: Port Far-end IP Addr : Port
Q.931: 12B1217 xxx.xxx.xxx.xxx : nnnnn xxx.xxx.xxx.xxx : nnnnn
H.245: 12B1217 xxx.xxx.xxx.xxx : nnnnn xxx.xxx.xxx.xxx : nnnnn
G.711-MU Audio: 12B11 xxx.xxx.xxx.xxx : nnnnn xxx.xxx.xxx.xxx
: nnnnn
H.245 Tunneled in Q.931? no
Audio Connection Type: ip hairpin