Maintenance Commands
555-233-143
7-452 Issue 1 May 2002
!
WARNING:
Since the clear long option clears every counter if the test passes, it is
possible for firmware counters to be cleared even though a problem exists.
In some cases customer service might degrade since calls may be routed
over defective equipment.
Output
The following example shows the output for the test pkt port-network 1
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field Descriptions
Port
A port network number (1 44).
Maintenance
Name
The name of maintenance object being tested.
Alt. Name
Not applicable.
Test No
The test being executed.
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer to the
detailed list of the codes by test number for each MO.
test pkt port-network 1
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
PN 01 PKT-BUS 571 PASS
PN 01 PKT-BUS 572 PASS
PN 01 PKT-BUS 573 PASS
Command successfully completed