AC-POWER
Issue 1 May 2002
8-9555-233-143
AC-POWER for DC-Powered Systems
NOTE:
In a DC-powered multicarrier cabinet, the AC-POWER MO exists, but
serves no functional purpose. Because the system cannot determine the
type of power used, the AC-POWER test should always pass or abort. The
maintenance strategy for power components in DC cabinets is described in
‘‘CARR-POW (Carrier Power Supply)’’ on page 8-393.
S8700 Multi-Connect supports three different cabinet types for EPNs: multicarrier
cabinets (MCCs), single-carrier cabinets (SCCs), and 19-inch rack mounted
cabinets. Every type may be powered by either an AC or DC power source.
Environmental maintenance differs according to a cabinet’s type and its power
supply.
Error Log Entries and Test to Clear Values
MO’s Name (in
Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
AC-POWER WARNING test environment UU
1
1. UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC).
AC Power
Table 8-3. AC Power Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Of
f
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test environment UU sh r 1
513 Any AC Power Query test (#78) WARNING OFF test environment UU sh r 1