Maintenance-Object Repair Procedures
555-233-143
8-30 Issue 1 May 2002
1000 ABORT System resources required to run this test are not available. The port may be
active.
1. Use the display port UUCSSpp command to determine the voice port
extension of the port. Use the status station command to determine the
service state of the port. If the port is active, it is unavailable for certain
tests. Refer to Status commands in Chapter 7, ‘‘Maintenance
Commands’’, for a full description of every possible state. Wait until the
port is idle before testing.
2. If the ports status is idle, retry the command at 1-minute intervals up to 5
times.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
1004 ABORT The port was put in use during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the voice port
extension of the port. Use the status station command to determine the
service state of the port. If the port is active, it is unavailable for certain
tests. Refer to Status commands in Chapter 7, ‘‘Maintenance
Commands’’ for explanations of every possible state. Wait until the port is
idle before testing.
1020 ABORT Test disabled via background testing. Use the status station command to
determine when the voice port is available for testing.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
1, 2 FAIL The NPE of the tested port was found to be transmitting in error. This causes
noisy and unreliable connections. Failure code 1 indicates that the Crosstalk
test failed on the primary channel. Failure code 2 indicates that the Crosstalk
test failed on the secondary channel.
1. Replace the circuit pack (see caution at the beginning of this section).
Table 8-10. Test #9 NPE Crosstalk Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page