ADX16D-P (16-Port AUDIX Digital Port)
Issue 1 May 2002
8-33555-233-143
None FAIL The test failed for reasons external to the AUDIX.
1. Run circuit pack tests to check the IPSI Tone Generator circuit or Tone
Generator circuit pack and the IPSI Tone Detector circuit or Tone Detector
circuit pack using test board UUCSS s.
2. Resolve any problems detected on the Tone Generator circuit or Tone
Detector circuit.
3. If both circuit packs are functioning properly and the test still fails, replace
the AUDIX (see caution at the beginning of this section).
PASS Voice and Control Channel Local Loop test passed. Every channel are
transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this test up to 10
times, and see whether it continues to pass.
2. If complaints still exist, examine the connections.
Table 8-11. Test #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page