ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 1 May 2002
8-37555-233-143
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the port is active, it is unavailable for certain tests. Wait
until the port is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
1001 ABORT Could not allocate the necessary system resources to run this test.
1
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
then retry the command at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. Retry the command at 1-minute intervals up to 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the port is active, it is unavailable for certain tests. Wait
until the port is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
1005 ABORT This condition indicates that the test is not applicable when the analog port is
used in a combined modem pool. This error can be ignored.
1018 ABORT Test disabled via administration.
1. To enable the test for the particular analog station being tested, enter the
change station extension command and change the
Test? field on the
Station Form to y.
2000 ABORT Response to the test request was not received within the allowable time period.
2012 ABORT System could not respond to this request.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Table 8-13. Test #6 NPE Crosstalk Test Continued
Error
Code
Tes t
Result Description / Recommendation