ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 1 May 2002
8-39555-233-143
Conference Circuit Test (#7)
This test verifies that the NPE channel for the port being tested can correctly
perform the conferencing function.
Table 8-14. Test #7 Conference Circuit Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run test are not available. The port may be busy
with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the port is active, wait until it is idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the port is active, wait until it is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
1018 ABORT Test disabled by administration. This only applies to analog stations.
1. To enable the test for the analog station being tested, enter the change
station extension command and change the
Test? field on the Station
Form from to y.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL The NPE of the tested port did not conference the tones correctly. This causes
noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port can correctly conference multiple connections. User-reported troubles
on this port should be investigated by using other port tests and by examining
station, trunk, or external wiring.