ALARM-PT (ALARM PORT)
Issue 1 May 2002
8-45555-233-143
Station Status and Translation Audits and
Updates Test (#36)
For an analog line port that is administered as an external alarm, this test is
limited to updating the software with the switchhook state.
Table 8-18. Test #36 Station Status and Translation Audits and Updates
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1004 ABORT The port received an EXT-DEV failure during the test. The test has been
aborted.
1. Before retesting, enter test external-device-alarm port UUCSSpp to
determine whether the port is reporting an EXT-DEV failure.
2. If the port has no EXT-DEV failures, retry the command at 1-minute
intervals up to 5 times.
1006 ABORT This port has been busied out by command.
1. Check Error Log for Error Type 18 (port busied out). If present, release the
port with the release port UUCSSpp command and run the test again.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 FAIL This failure does not indicate a hardware problem. The switchhook audit failed,
this condition may occur when the audit is performed at the same time that the
terminal equipment goes off-hook.
1. Before retesting, enter test external-device-alarm port UUCSSpp to
determine whether the port is reporting an EXT-DEV failure. Wait until the
port has no EXT-DEV failures.
2. If the port has no EXT-DEV failures, retry the command at 1-minute
intervals up to 5 times.
7 FAIL The translation update failed. This does not indicate a hardware problem but
may be an internal software error.
PASS The software and the port processor have the same status.
Continued on next page