Safety Precautions
Issue 1 May 2002
4-3555-233-143
EMBEDDED AUDIX System’s Power Procedures
Manually Power Down AUDIX System
A amber caution sticker on the system’s power unit notifies technicians to shut
down the EMBEDDED AUDIX system prior to powering down the system.
1. Using a pointed object, such as a paper clip or pen (do not use a pencil),
press the Boot/Shutdown button. The button is located at the top right
portion of the front panel.
2. Hold the Boot/Shutdown button in until the LCD display flashes the
message MSHUT.
3. Release the Boot/Shutdown button.
NOTE:
The EMBEDDED AUDIX system takes about five minutes to shut
down. The “heartbeat” indication on the display continues to flash.
Manually Power Up AUDIX System
1. Using a pointed object such as a paper clip or a pen (do not use a pencil),
press the Boot/Shutdown button.
2. Hold the Boot/Shutdown button in until the display indicates the message,
BTEST, steady on.
3. Release the Boot/Shutdown button. The EMBEDDED AUDIX system takes
approximately 5 minutes to power up.
■ The display has the following sequence of steady-on messages:
— OSINIT
— OS
— AINIT
— ADX
■ The EMBEDDED AUDIX system is now powered up. When the
system is in the active state, the display indicates ADX, and the red
LED is off.
4. When powering up, the EMBEDDED AUDIX system automatically reboots.
This sequence may show an MD or MJ ADX alarm in the display until the
system has powered up. When the system has completed its power-up
sequence, the display reads: ADX.