ANL-16-L (16-Port Analog Line)
Issue 1 May 2002
8-55555-233-143
FAIL The port’s battery feed chip is unable to supply sufficient power to the terminal
equipment. This could be a marginal test, and the terminal equipment may be
operating satisfactorily.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, determine whether the customer is experiencing
problems on this line. Replace the circuit pack only if the customer is
experiencing problems.
PASS The port’s battery feed chip is able to provide power to the station equipment to
detect on-/off-hook, but may not be able to supply power for touch-tones. If
touch-tones are inoperative on this station, then replace the circuit pack
because this port is inoperative. User-reported troubles on this port should be
investigated by using other port tests, by examining station wiring, or by
examining the station.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use the list config
command, and resolve any problems.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port. If
not, verify that a valid board is inserted.
Table 8-22. Test #35 Battery Feed Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page