ANL-16-L (16-Port Analog Line)
Issue 1 May 2002
8-57555-233-143
7 FAIL The translation update failed. There may be an internal software error. The
ringer update was not performed because of this failure.
8 FAIL This does not indicate a hardware problem. There may be an internal software
error. The ringer update failed.
1. Retry the command at 1-minute intervals up to 5 times.
PASS The software and the port processor have the same status. User-reported
troubles on this port should be investigated by using other port tests, by
examining station wiring, or by examining the station.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use the list config
command and resolve problems.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port. If
not, verify that a valid board is inserted.
Table 8-23. Test #36 Station Status and Translation Audits and Updates — Continued
Error
Code
Tes t
Result Description / Recommendation