ANL-LINE, ANL-NE-L (8-Port Analog Line)
Issue 1 May 2002
8-87555-233-143
Table 8-35. Test #35 Battery Feed Test Results
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call. This result is also reported for the system’s
Music-on-Hold port when it is off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the station’s extension. Enter
status station extension to determine the service state of the port. If the
port is active, it will be unavailable for certain tests. Wait until the port is
idle before retesting.
2. When the port is idle, retry the command at 1-minute intervals up to 5
times.
1004 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the service state indicates that the port is active, then
the port is unavailable for certain tests. (Refer to Chapter 7, ‘‘Maintenance
Commands’’, for a full description of every possible state.) Wait until the
port is idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to abort and the port is idle, escalate the problem.
1005 ABORT The test was aborted due to a configuration problem. This code results under
either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
— TN742 vintages 13,14, and 15
— TN769 vintages 3, 4, and 5
1018 ABORT Test disabled via administration. The default for the
Test? field on the is y;
thus, you may want to determine why this field has been set to “n” on this
station (this may be due to the ringing application Test E48, which can be
customer or terminal disturbing).
1. To enable the test for a particular station, enter change station extension
and set the
Test? field to y.
Continued on next page