ANL-LINE, ANL-NE-L (8-Port Analog Line)
Issue 1 May 2002
8-89555-233-143
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use the list config
command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port. If
not, dispatch to verify that a valid board is inserted.
Table 8-35. Test #35 Battery Feed Test Results — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page