Maintenance-Object Repair Procedures
555-233-143
8-94 Issue 1 May 2002
Table 8-37. Test #47 Loop Around and Conference Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7 ABORT The port was seized by a user for a valid call.
1. Enter display port UUCSSpp to determine the stations extension. Enter
status station extension to determine the service state of the port. If the
port is active, it will be unavailable for certain tests. Wait until the port is
idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test were not available. The port may be
busy with a valid call. (This could be a Music-on-Hold port.)
1. Enter display port UUCSSpp to determine the stations extension. Enter
status station extension to determine the service state of the port. If the
port is active, it will be unavailable for certain tests. Wait until the port is
idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out-of-service.
1. Resolve TTR-LEV errors.
2. Resolve TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
1004 ABORT The port has been seized for a valid call during the conference or noise test.
1. If the circuit pack is a TN742 of Vintage 10 or less, this test is not valid.
Otherwise, proceed with step 2.
2. When the port is available for testing, retry the command at 1-minute
intervals up to 5 times.
Continued on next page