EasyManua.ls Logo

Avaya S8700 - Page 837

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AN-LN-PT (Analog Line Port)
Issue 1 May 2002
8-115555-233-143
1008 ABORT A ringing circuit could not be allocated. Either every ringing circuit is active, the
ringing generator is defective, or it is incorrectly wired.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error Log.
3. If ABORT 1008 occurs for this test on other circuit packs as well, the
ringing generator may be defective or is incorrectly wired (see
‘‘RING-GEN’’ on page 8-1357.
4. If an ABORT 1008 does not occur on other ports, then all four ring phases
are active.
1018 ABORT Administration has disabled the test. The default for the
Test? field on the
station form is y. Determine why this field has been set to n on this station (this
may be due to the ringing application Test 48, which can be disturbing to
customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
station extension.
2. Change the Test? field on the station form to y.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The terminal equipment is not connected to the circuit pack. Some terminal
equipment, such as modems, may fail even when connected properly.
1. Remotely test the terminal equipment.
2. If the test fails again, resolve any RING-GEN errors in the error log, if
present.
3. Check all of the wiring between the station equipment and the switch.
Then, run the test again.
4. If the test still fails, the terminal equipment may be defective. Check and
replace it, if necessary.
5. Some terminal equipment might fail even when it is connected properly. If
this is the case, disable the test using the change station extension
command (enter n into the
Test field). Note that this action also disables
Tests 6, 7, 35, and 161 on this port.
Table 8-44. Test #48 Station Present Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page

Table of Contents

Other manuals for Avaya S8700

Related product manuals