Maintenance-Object Repair Procedures
555-233-143
8-118 Issue 1 May 2002
1004 ABORT A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station extension command to determine the service
state of the port.
3. If the port is active, wait until it is idle before testing. Retry the command at
1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1005 ABORT This test was aborted due to a configuration problem. The test is not applicable
for this type of analog port. This error can be ignored.
1018 ABORT Administration has disabled the test. The default for the
Test? field on the
station form is y. Determine why this field has been set to n on this station (this
may be due to the ringing application Test 48, which can be disturbing to
customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
station extension.
2. Change the Test? field on the station form to y.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The reflective loop-around test failed. This could cause noisy or unreliable
connections, or users calling this port may hear an echo. The problem can also
be off-board.
1. Since a line seizure may affect the test, repeat the test at 1-minute
intervals up to 5 times.
2. Using the test board UUCSS short command, run circuit pack tests to
check the Tone Generator and the Tone Detector circuits on the IPSIs or
the Tone Generator/Tone Detector circuit packs.
3. Resolve any problems on the Tone Generator or the Tone Detector circuit.
4. If the Tone Generator and Tone Detector circuits are functioning properly,
determine whether a voice terminal is connected and wired properly.
Resolve any problems found.
5. If the test still fails, replace the analog line circuit pack.
PASS The port provides an analog transmission path to the station equipment.
Investigate user-reported troubles on this port by running other port tests, by
examining station wiring, or by inspecting the station.
Table 8-45. Test #161 Loop-Around Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page