Maintenance-Object Repair Procedures
555-233-143
8-184 Issue 1 May 2002
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. Error Type 18: D channel busied out; no calls possible over this D channel.
b. Error Type 130: circuit pack removed or has been insane for more than
11 minutes. To clear the error, reinsert or replace the circuit pack.
c. Error Type 1793: ATM Trunk circuit pack failed the Signaling Link Board
check (#643). Resolve any ATM-TRK errors in the Error Log.
System Technician-Demanded Tests:
Descriptions and Error Codes
The command to test the ATM-DCH MO is test port UUCSSpp, where pp is for
ports 9-32.
Table 8-75. ATM D-channel Error Log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp
2
2. pp is for ports 9–32.
18 (a) 0 busyout port UUCSSpp WARNING OFF release port UUCSSpp
130 (b) None WARNING ON test port UUCSSpp
1793 (c) Signaling Link Board
check (#643)
test board UUCSS l
Continued on next page
Table 8-76. System Technician-Demanded Tests: ATM-DCH
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive, ND = Nondestructive
Signaling Link Board check (#643) X X ND