ATM-EI (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-219555-233-143
Table 8-91. ATM Board Framer Loop-Around Test (#1260)
Error
Code
Tes t
Result Description / Recommendation
1002 ABORT The system could not allocate timeslots for the test. The system could be
under heavy traffic conditions or it could have timeslots out of service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 3 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
2. Verify that at least one Tone Detector resides in this EPN. (Even without a
TTR-LEV error, the tested circuit packs EPN could be missing a Tone
Detector.)
If missing, the test always aborts for this circuit pack, without harming the
system.
NOTE:
A TN2182 Tone-Clock circuit pack must be of vintage B or newer. If an
earlier vintage circuit pack resides in an EPN, this test always aborts
with this abort code.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the command at 1-minute intervals up to 3
times.
1015 ABORT The ATM-EI circuit pack has not been busied out.
1. Busyout the ATM-Expansion Interface circuit pack, then repeat the test
board UUCSS long command.
1031 ABORT If the ATM Expansion Interface circuit pack is in an EPN and is on the active
PNC, this test cannot be executed.
1. If PNC Duplication is enabled, attempt to make the standby PNC active
with the reset pnc interchange command.
2. If the PNC Interchange is successful, rerun the test.
1033 ABORT The ATM-EI circuit pack is absent.
1. Issue the list atm pnc command to verify that switch recognizes the circuit
pack.
2. Retry the command.
1139 ABORT The packet bus in the EPN where this ATM-EI board resides has a major alarm
against it. This test needs to use the alarmed EPNs packet bus.
1. Resolve any PKT-BUS problems.
2. Retry the command.