Maintenance-Object Repair Procedures
555-233-143
8-224 Issue 1 May 2002
Table 8-93. ATM Board Reset (#1256)
Error
Code
Tes t
Result Description / Recommendation
1386 ABORT No Active EAL to the board. This error applies only if the board under test is in
EPN. Check the error logs for SYS-LINK errors against the EPN where the
ATM-EI resides, and take appropriate diagnostic action for the SYS-LINK.
1015 ABORT This test cannot be run because the ATM-EI circuit pack has not been busied
out.
1. Busyout the ATM circuit pack, then repeat the test board UUCSS long
command.
1407 ABORT 1. Perform a PNC Interchange
2. Try to reset the board again.
None ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort escalate the problem.
2000 ABORT Did not receive the SANITY response in the given time.
1. Wait for 5 minutes and see if board is visible to the system by using list
config all command.
2. If the board is visible, run the test again. If same abort code results,
escalate the problem.
3. If the board is not visible to the system with the list configuration all
command, reseat the board.
4. If the board is still not recognized by the system, replace the board.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABORT Internal system error
1. Try to reset the board again.
1 FAIL The circuit pack failed to reset.
2 FAIL The circuit pack failed to restart.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
PASS The ATM-EI circuit pack is successfully reset.
1. If the status port-network command still indicates that this link is down, it
is possible that one or both of the ATM-EI circuit packs are busied out.
2. If the links do not come up after reset, review the error logs and take
appropriate diagnostic action.
Continued on next page