Maintenance-Object Repair Procedures
555-233-143
8-252 Issue 1 May 2002
Error Log Entries and Test to Clear Values
NOTE:
The list config port-network command gives the cabinet number
associated with an EPN.
Table 8-103. Error Log Encode Field Decoding
Field Variable Name Values Description
cAlarm Type 0
1
Alarm retired
MAJOR or MINOR alarm on any PNC component
x
Fault class; see
description for
contributing MOs
0 EAL (Expansion Archangel Link - EXP-PN) carries
CCMS messages
1 PACL (ATM-EI) carries ATM signaling commands
from Call Processing to the remote ATM-EI circuit
packs
2 PNC hardware (providing connectivity of EPN-to-EPN
or -ATM-EI)
5 BFDL (bearer fault detection link) solely for the
purpose of detecting bearer faults
pp Port-network number 0–63 0–2 for constraint class (this is an internal number;
add 1 for external port number)
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
18 None busy PNC-DUP WARNING ON release pnc-dup