Maintenance-Object Repair Procedures
555-233-143
8-254 Issue 1 May 2002
When there are problems with ATM-SGRP (ATM signaling group), also
investigate:
■ ‘‘ATM-DCH (ATM D-Channel Port)’’
■ ‘‘ATM-BCH (ATM B-Channel Trunk)’’
■ ‘‘SYS-LINK (System Links)’’
■ ‘‘PKT-BUS (Packet Bus)’’
Error Log Entries and Test to Clear Values
Notes
a. Error Type 1: switch sent a message to the far-end switch or terminal
adapter, and the far end did not respond in the allotted time. Possible
causes include link failure and congestion or outage at the far end. The
Aux Data field contains layer-3 protocol information used by internal
counters.
Table 8-105. ATM-SGRP Signaling Group Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/
Off
Board Test to Clear Value
00Any Any test sig-group grp#
1 (a) Any None
18 (b) MO busied out
257 (c) Any None test sig-group grp#
769 (d) Any Primary Signaling Link
Hardware check (#636)
test sig-group grp#
1281 (e) Any Secondary Signaling Link
Hardware check (#639)
test sig-group grp#
1793 (f) Any Layer 2 Status test (#647) WARNING OFF test sig-group grp#
2305 (g) Any Remote Layer 3 Query
test (#637)
MINOR OFF test sig-group grp#
3585 (h) Port
number
None
3840 -
3928 (i)
Port
number
None