Maintenance-Object Repair Procedures
555-233-143
8-268 Issue 1 May 2002
1. Check if the primary DS1 interface circuit pack is inserted in the
carrier with the list configuration board UUCSS command.
2. Verify that the administered primary reference matches the DS1
reference from the network synchronization plan.
3. Test the primary DS1 interface circuit pack with the test board
UUCSS long command. Check the Error Log for DS1-BD or
UDS1-BD errors and see ‘‘DS1-BD (DS1 Interface Circuit Pack)’’ or
‘‘UDS1-BD (UDS1 Interface Circuit Pack)’’ on page 8-1707 to
resolve any errors associated with the primary DS1 (DS1 or UDS1)
interface circuit pack. If the only errors against DS1-BD or
UDS1-BD are slip errors, then follow the procedures described in
the troubleshooting section above. If no errors are listed in the Error
Log for the primary DS1 interface circuit pack, continue with the
following steps.
4. Test the active Tone-Clock circuit in the master port network with the
test Tone-Clock UUC long command. Check the Error Log for
TDM-CLK errors and verify that TDM Bus Clock Test #148 (TDM
Bus Clock Circuit Status Inquiry test) passes successfully. If Test
#148 fails with an Error Code 2 through 32, see ‘‘TDM-CLK (TDM
Bus Clock)’’ on page 8-1604 to resolve the problem.
b. Error Type 257: problem with the secondary DS1 reference. It is cleared
when the secondary reference is restored. Refer to note (a) to resolve this
error substituting secondary for primary in the preceding resolution steps.
c. Error Type 513: the ATM switch clock is inferred to be providing the timing
source for the system. The primary and secondary (if administered) are
not providing a valid timing signal. Investigate errors 1 and 257 to resolve
this error.
d. Error Type 1537: over half of the DS1s that are administered with slip
detection enabled through the Slip Detection? field set to y are
experiencing slips.
e. Error Type 1793: inferred excessive switching of system synchronization
references has occurred. When this error occurs, it is inferred that the ATM
switch clock has become the synchronization reference for the system.
1. Check for timing loops and resolve any loops that exist.
2. Test the active Tone-Clock circuit in the master port network with the
test Tone-Clock UUC long command.
Check the Error Log for TDM-CLK errors, and verify that TDM Bus
Clock Circuit Status Inquiry test (#148) passes successfully.
If Test #148 fails with an Error Code 2–32, see ‘‘TDM-CLK (TDM
Bus Clock)’’ on page 8-1604 to resolve the problem. If not, continue
with the following steps.
3. For Duplicated Tone-Clock circuit packs in the master port network:
Switch Tone-Clock circuit packs on the master port network with the
set Tone-Clock UUC command.