Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
137
of 820
4
Figure 71: Torque current limit
Bit 1 and 3:
Dependent of the motor type and the controller FW version the following modes are avail-
able to calculate the "Max. torque current" Z19.8.
X = independent of that
Standard load mode (default setting):
m Dependent of the field weakening and the external total current limit
m Dependent of 138.1 bit 1 at the ASM
m Z19.8 is calculated from "Max. drive current actual value" Z19.5 and "Max. field
current amplitude" Z19.7 (at the ASM with 138.1 bit 1 = 1: "lsd set value" Z47.2
instead of the parameter Z19.7).
Current mode
m Independent of the field weakening and the external total current limit.
m Independent of 138.1 bit 1.
m Z19.8 is calculated from the "Max. drive current" Z19.6 and the "Magnetizing cur-
rent" Z107.14 (ASM) or field weakening = 0 (SM).
Details about the effect of the standardization modes in the "Max. torque current" are de-
scribed in the parameter Z19.8.
Q1
Q1
Q2
Q2
Q3
Q3
Q4
Q4
5000_0203_rev01_int.cdr
Iq set value
Iq set value
Speed actual value
Speed actual value
Limit mot
Limit TD2
Limit TD1
Limit gen
Bit 1 Bit 3 Motor
type
Controller
FW
Standardizing modes
Standard load
factor mode
Load factor
mode
ASM-IsdMax
Current mode
X X X before V1.13 yes -- --
0 X ASM before V1.13 yes -- --
1 X ASM before V1.13 -- yes --
X 0 X from V1.13 yes -- --
0 0 ASM from V1.13 yes -- --
1 0 ASM from V1.13 -- yes --
X 1 X from V1.13 -- -- yes