Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
197
of 820
4
The cause of error will be displayed in this parameter.
Not generally all error messages were supported (see Z137.36 Alarm mask).
The controller responds to a set error bit with a corresponding error (error numbers 406
to 412).
137.38 Warning mask
The parameter is only valid for EnDat
®
encoders.
The supported warnings of the connected encoder type are shown.
137.39 Warning buffer
The parameter is only valid for EnDat
®
encoders.
The warnings of the connected encoder type are displayed in this parameter. The ex-
ceeded requirements of tolerance for specific encoder internal values are displayed.
It is not assumed that position value are wrong at warnings contrary to error messages.
Bit Monitoring according to
0 1: Illumination failure
1 1: Signal amplitude faulty
2 1: Position value faulty
3 1: Overvoltage occurred
4 1: Undervoltage supply
5 1: Overcurrent occurred
6 1: Battery change needed
Residual Reserved
Bit Supported warnings
0 1: Collision of frequency
1 1: Excess temperature
2 1: Lighting controller reserve
3 1: Battery load
4 1: Reference point crossed
Residual Reserved