Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
233
of 820
4
125.8 General scaling
Standardization for all parameters for which no other suitable standardization exists. The
units of the value to be visualized will provide an indication of this (
Z125.1–, Z125.2–).
I.e. this standardization will be used also for related quantities with the unit [%].
125.9 Force scaling
Parameters with the units [N] will be normalized to [N / V] with this factor.
125.10 Current scaling
Parameters with the units [A] will be normalized to [A / V] with this factor.
125.11 Voltage scaling
Parameters with the units [V] will be normalized to [V / V] with this factor.
125.12 Position scaling
This standardization is used for parameter with the units [Inc], [degree], [mm] and [nm].
125.13 Speed scaling
This standardization is used for parameter with the units [degree/s], [Rev/min], [Inc/ms],
[mm/s], [degree/mm] and [Inc/tab].
125.14 Acceleration scaling
This standardization is used for parameter with the units [Inc/ms
2
], [degree/s
2
] and
[Inc/tab
2
].
125.15 Torque scaling
Parameters with the units [Nm] will be normalized to [Nm / V] with this factor.