Configuration
Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
316
of 820
4.4
170.31 Error module number
This parameter shows at module related errors the number of the module or the POU
where the error has occurred.
170.32 Error line number
This parameter shows at module related errors the number of the faulty intermediate code
instruction.
170.33 Error POU code type
At module related errors this parameter shows the type of the POU, which caused the er-
ror.
It is defined:
170.34 Error module name
This parameter shows at module related errors the name of the POU, where an error has
occurred.
170.50 Run time task RT0
This parameter shows the execution time of the PLC code in the RT0 time slice.
170.51 Run time task RT1
This parameter shows the execution time of the PLC code in the RT1 time slice.
Value Meaning
0 Reserved
1 Initialization code
2 Regular process code