179.14 Minimum software position limit
DS402 Factor Group object 0x607D.01 (negative limit switch for all position controlled op-
erating modes with position weighting corresponding to ZGeneral information from
page 318).
179.15 Maximum software position limit
DS402 Factor Group object 0x607D.02 (positive limit switch for all position controlled op-
erating modes with position weighting corresponding to ZGeneral information from
page 318).
179.16 Touch probe pos1 pos value
DS402 Factor Group object 0x60BA (touch probe value from revolutions and angle
scaled with position weighting corresponding to
ZGeneral informationfrom page 318).
Notice: The touch probe must be parameterized adequately, see notes on Zpage 322.
179.17 Touch probe pos1 neg value
DS402 Factor Group object 0x60BB (touch probe value from revolutions and angle
scaled with position weighting corresponding to
ZGeneral informationfrom page 318).
Notice: The touch probe must be parameterized adequately, see notes on Zpage 322.
179.18 Touch probe pos2 pos value
DS402 Factor Group object 0x60BC (touch probe value from revolutions and angle
scaled with position weighting corresponding to
ZGeneral informationfrom page 318).
Notice: The touch probe must be parameterized adequately, see notes on Zpage 322.
179.19 Touch probe pos2 neg value
DS402 Factor Group object 0x60BD (touch probe value from revolutions and angle
scaled with position weighting corresponding to
ZGeneral informationfrom page 318).
Notice: The touch probe must be parameterized adequately, see notes on Zpage 322.