Management
Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
352
of 820
4.5
- a set value lock via control word bit 12
- a stop triggered by the end switch monitoring
m Coupled operation (operation mode -12)
0->1 The sequence was changed successfully (check-back for bit 5 Z108.1)
Bit 13:
m Reference run operation (Operating mode 6):
The bit is set if the reference run has been interrupted by an internal error.
The bit is deleted if the error is reset.
m Coupled operation (operation mode -12)
0->1 Change of gear factor was made (check-back for Bit 8 Z108.1)