4.5
Pulses are inhibited (drive is without torque)
If the drive is suddenly without torque due to a pulse inhibit (HW input or response to
QUICK STOP/SHUT-DOWN/INHIBIT/drive error), the brake could be applied immediate
-
ly or when the speed threshold (see above) is reached. With a suspended load, it is rec-
ommended that the brake be allowed to be applied immediately in this case (Z134.3
Bit 2 = 0) as the drive could be accelerated by the externally acting torque, with the result
that the speed threshold is not reached and the brake is not applied.
Figure 129: Braking procedure in the "Automatic" brake control mode