Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
413
of 820
4
110.3 Output
Output value of the ramp function generator.
Standardization:
100% = Maximum drive speed (Z110.13, [rpm])
110.4 Input 32-bit
Ramp generator input value with 32-bit resolution. This input is activated instead of the
16-bit input by means of
Z110.2 Ramp Function Generator Mode Bit 5 = 0.
Standardization:
100% = Maximum drive speed (Z110.13, [rpm])
110.5 Input 16-bit
Ramp generator input value with 16-bit resolution. This input is activated instead of the
32-bit input by means of
Z110.2 Ramp Function Generator Mode Bit 5 = 1.
Standardization:
100% = Maximum drive speed (Z110.13, [rpm])
110.6 Ramp-up time
Acceleration ramp for the speed-controlled operating modes.
The time selected here applies to a 100% set value change
110.7 Ramp-down time
Deceleration ramp for the speed-controlled operating modes.
The time selected here applies to a 100% set value change
110.8 Quick stop time
The Quick Stop ramp operates during all Quick Stop procedures, not only in the speed-
controlled operating modes.
Depending on bit 7 of the parameter Z110.2 Mode the quick stop time applies to
m change of set value from 100% to 0% Z110.2 bit 7 = 0,