Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
419
of 820
4
132.3 Output
Output of the set value generator
The output value is written to the preset target parameter 132.4.
132.4 Target number output
Selection of the target parameter to which the set value generator writes. All cyclic writ-
able parameters are allowed.
132.10 Set value 1
Set Value in Time Zone 1 of the set value generator.
When the set value generator is started, a check is made to make sure that the set value
lies within the range of values in the target parameter and if necessary an error message
is issued.
132.11 Duration zone 1
Duration of Time Zone 1 for the set value generator in ms. The associated set value is
applied to the output of the generator for this duration.
132.12 Set value 2
Set Value in Time Zone 2 of the set value generator.
When the set value generator is started, a check is made to make sure that the set value
lies within the range of values in the target parameter and if necessary an error message
is issued.
4 0: No error
1: Error
31…5 Reserved
Bit no. Meaning