142.15 Factor field weak threshold
This factor defines the set voltage from which the field weakening starts. The provided
voltage is multiplied with this factor and this way a relative setting of the set voltage is pos
-
sible. This factor should be lower than Z142.21.
142.19 P-Gain breakdown torque controller
Proportional gain of the breakdown torque controller.
142.20 Integral action time breakdown torque control
Integral action time of the breakdown torque controller.
142.21 Factor breakdown torque threshold
This factor defines the set voltage from which the breakdown torque controller starts. The
provided voltage is multiplied with this factor and therefore a relative setting of the set volt
-
age is possible. This factor should be higher than Z142.15.
142.22 Breakdown torque control output
The output from the breakdown torque controller is dimensionless and is between 0 and
1. The limit level is determined. The output is multiplied by the maximum total current
(
Z19.6) and leads to Z138.18.