4
The temperature compensation is made automatically if the motor temperature monitor-
ing is activated (Z128.2 bits 0 to 7). The following applies if the temperature monitoring
is deactivated:
The displayed value in the parameter Z19.32 "Rotor time constant" is not changed by
the temperature compensation.
The temperature compensation applies to the following:
m Field orientation of the ASM with an encoder
F
2 Tm act
F
2 warm
=