Operating Modes
Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
644
of 820
4.8
127.12 Averaging zero speed detection
This parameter is used for the standstill detection at notch position search method 1. The
higher the value is, the lower the measured motor movement may be.
Condition for standstill Z127.12– * Phi / ms < Traversing angle (Z127.9–).
This parameter is used at notch position search method 1, only.
127.13 Actual value mech. delta angle
Display of the measured mechanic movement at notch position search method 1.
65536 Inc of the parameter accord to 360 degrees.