Error descriptions
Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
748
of 820
5.5
133 The FPGA has booted the fallback ver-
sion
The FPGA has booted the fallback version Pulse block
135 Error while programming to flash Error while programming to flash No response
137 Time dial computation time overrun It is being monitored whether the time dials exceed the run time of
MAX_ZS_TIME_LIMIT_IN_TICK = 60 µs too frequently.
Monitoring in remaining time, threshold: per second = 1000*16 ZS,
10% of that: 1600 overruns per second
Pulse block
138 Cycle2 duration too long Cycle2 duration more than 1% too long in relation to one second.
The CPU is overloaded, computation too great.
Pulse block
139 Drive not synchronous with RT fieldbus
(Warning)
This warning message is issued when the synchronization of the
drive with the fieldbus is activated (Parameter
Z156.1), but it has
not yet occurred (Parameter Z156.2). The message occurs regard-
less of the fieldbus status (operational / not operational) and will be
deleted when the drive is synchronous.
Required for better error diagnosis because the drive cannot be
released when synchronicity is required but has not been achieved.
No response
140 General firmware error, e.g. switch General firmware error, e.g. switch Pulse block
141 Operating system error Error in context with the operating system Pulse block
142 Method not implemented Method not implemented Pulse block
144 invalid file type invalid file type No response
145 File already open File already open No response
146 Maximum size of file reached (writing
reading)
Maximum size of file reached (writing reading) No response
147 File not opened File not opened No response
148 File not opened for this access (Read
Write access)
File not opened for this access (Read Write access) No response
149 Indicated ID wrong Indicated ID wrong No response
150 Indicated index does not exist (too
large)
Indicated index does not exist (too large) No response
151 Parameter element cannot be written Parameter element cannot be written No response
152 External access not permitted External access not permitted No response
153 Value less minimum value Value less minimum value No response
154 Value greater maximum value Value greater maximum value No response
155 Value errory Value errory No response
156 Value cannot be changed due to the
operating condition
Value cannot be changed due to the operating condition No response
157 wrong axis index wrong axis index No response
158 Format information wrong Format information wrong No response
159 Error while reading system data Error while reading system data from flash No response
168 No write permission for the actual
access level
Parameter cannot be changed due to the access protection. No
write permission for the actual access level.
No response
169 Application error to test the error
responses
Application error to test the error reactions. The error is enabled by
value 5 on parameter 100.1 Info-Manager Error command for one
single time. The error can be used to test the different error reactions
without having to enable a „real“ error, e.g. return.
No response
Error
num-
ber
Brief error text Error description Default set-
ting for
Error
Response