Error descriptions
Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
768
of 820
5.5
2300 FPGA_RSP record is not available for
READING
No response
2400 Invalid "Device type" in login message Invalid "Device type" in login message No response
2401 Invalid command for a confirm mes-
sage
Invalid command for a confirm message No response
2402 Wrong connection ID from server Wrong connection ID from server No response
2403 File data on server and client are not
equal
File data on server and client are not equal No response
2404 Error with erasing file data Error with erasing file data No response
2405 Erasing file data is busy Erasing file data is busy No response
2406 Error with writing file data Error with writing file data No response
2407 Writing file data is busy Writing file data is busy No response
2408 Error with reading file data Error with reading file data No response
2409 Invalid parameter file on the SAF-mod-
ule
Invalid parameter file on SAF-module No response
2410 Processing of parameter file is active Processing of the parameter file is active No response
2411 Invalid safe parameter file on SAF-
module
Invalid safe parameter file on SAF-module No response
2412 Processing of safe parameter file is
active
Processing of safe parameter file is active No response
2413 The transmit process is busy The transmit process is busy No response
2414 The receive process is busy The receive process is busy No response
2415 Timeout of transmit process Timeout of transmit process No response
2416 Timeout of receive process Timeout of receive process No response
2417 Build the list or parameter is busy Build the list or parameter is busy No response
2418 Module change to lower safety level A module change happened. The actual module has a lower safety
level than the former one. The controller must not be operated.
m Error reset:
Pulse block, resetting not possible
Pulse block
2419 Module change from SAF-003 to
SAF-002
Module change from SAF-003 to SAF-002. The controller must not
be operated.
m Error reset:
Resetting not possible
Pulse block
2598 Last reserved error number for platform
error
Platform errors are reserved error numbers that may have different
levels of importance on each platform. This range of numbers is
reserved so that platform specific error numbers (e.g. Windows error
numbers) do not have to be defined as generally valid in rc.h. These
error numbers can then be used as return codes within the platform
and may thereby not be transferred externally.
No response
2700 Fb Set value generator Set Value < Min
(target parameter)
One or more set values of the set value generator (FbSwg) are
smaller than the minimum value of the selected target parameter.
Testing is carried out to prevent overrun effects while writing to the
target parameter.
No response
2701 Fb Set value generator Set Value >
Max (target parameter)
One or more set values of the set value generator (FbSwg) are
greater than the maximum value of the selected target parameter.
Testing is carried out to prevent overrun effects while writing to the
target parameter.
No response
Error
num-
ber
Brief error text Error description Default set-
ting for
Error
Response

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baumuller b maXX BM3000 and is the answer not in the manual?

Baumuller b maXX BM3000 Specifications

General IconGeneral
BrandBaumuller
Modelb maXX BM3000
CategoryMeasuring Instruments
LanguageEnglish