INSTALLATION AND STARTUP
1MANUL220 Belanger, Inc.® * PO BOX 5470. * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 8-3
Chapter 8 MixStir® Options Triple Foam and High-Pressure Wax
High Pressure Wax Option #2
The high-pressure wax option #2 allows for 3 programmable wax passes.
• One pass involves low pressure using both arms simultaneously.
• The second pass involves medium pressure using both arms simultaneously.
• The third pass involves high pressure using one arm at a time.
High pressure wax option #2 requires the Belanger® MixStir® tank to be installed.
MixStir® Tank Assembly and Installation
Locate the following parts:
1. Secure the High-Pressure Check Valve assembly and the supplied plug to the bottom of the MixStir®
tank. See the image below.