INSTALLATION AND STARTUP
18-2 Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL220
Chapter 18 Spot Free Rinse (RO) Option
Connections for Model 3000 GPD, Stand Mounted System
This section will explain all the feeds to and from the Spot Free Rinse (RO) system. The standard
100 Gallon Tank is pre-drilled at the factory.
Note: For more information, see the drawings on the following page.
Connect the inlet of the carbon tank to tap water with the 3/4” blue hose, which you cut to length.
The push lock fittings need to be pushed in until the hose bottoms out against the yellow collar, the fittings do not
require hose clamps on the inlet, tap water side.
Disconnect the fitting from the “Water Inlet” solenoid of the valve set; turn on tap water and flush the carbon tank to
drain it until the water runs clear.
Re-connect the hose from the carbon tank to the “Water Inlet” fitting on the inlet solenoid.
Drill a 2-1/2“ hole centered 4” from the bottom of the storage tank and install a 1-1/4“ tank adapter.
Be sure to vacuum out all plastic shavings from tank.
Install a float in the top of the tank by drilling a 1-3/4“ hole as close to the center as possible.
Remove the large gray nut from the float assembly.
Install a float with a rubber gasket to the inside of the tank and the replace nut.
Plug a two-prong twist lock into the connector in the bottom of the control box marked “Float Plug”.
Out to Pre-Filter
Housing
Reject Needle
Valve out to
Reject Flow Meter
To Pressure Switch
In from Membrane
Inlet Solenoid
Out to Drain
(Installer to make
connection)
In from Reject
Flow Meter
Out to Membrane
Tap Pressure
Re-circulation Valve
Flush Solenoid
In from Carbon Tank