Operational and error diagnosis
273 Application Warnings
367 Application warning status
Parameter
Application Warnings 273 displays the current warning.
Parameter
Application warning status 367 displays the warning at failure switch-off.
Meaning of code displayed by parameters
Application Warnings 273 and Application Warning
State
367:
Code
Warning status
A
00
00
NO WARNING
No warning message present.
A
00
01
BELT
Warning V-belt by Operation Mode 581.
A
00 40 SERVICE
Service of DC link or fan required. The time remaining until next ser-
vice has expired. At least for one of the parameters Operation Mode
Service Interval DC-link
1534 or Operation Mode Service Interval
Fan
1535 the setting “2 - Warning” is selected.
Service of DC-link required. The value of Service Interval DC-
link
1530 has reached the value 0%.
Service of fan required. The value of
Service Interval Fan 1531
has reached the value 0%.
A
00 80 User 1
The signal set on digital input
User Warning 1
1363 is active.
A
01 00 User 2
The signal set on digital input
User Warning 2
1364 is active.
Output signals
Application Warnings are signaled via digital signals.
216 -
Warning, application
1)
Signal if a message is output Application Warnings 273.
26 -
2)
1)
For linking to frequency inverter functions
2)
For output via a digital output. Select the signal source for one of the parameters 531, 532, 533,
554. See chapter 7.6.5 "Digital outputs".