3-51
Confidential
â– Error code E0
Program error
<User Check>
- Turn the power off and on.
â– Error code E1
Program error
<User Check>
- Turn the power off and on.
â– Error code E2
Temperature error of heat roller
(It is detected that the edge temperature is higher than 280°C.)
â– Error code E3
Drum motor origin sensor failure
Print Unable E0
Turn the power off and then back on again.
Print Unable E1
Turn off and on.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Print Unable E2
Turn the power off and then back on again.
Step Cause Remedy
1 Fuser unit failure Replace the fuser unit.
2 Eject front sensor PCB failure Replace the eject front sensor PCB ASSY.
3 Main PCB failure Replace the main PCB ASSY.
Print Unable E3
Turn the power off and then back on again.
Step Cause Remedy
1 Drum motor origin sensor PCB
failure
Replace the drum motor origin sensor
PCB ASSY.
2 Engine PCB failure Replace the engine PCB ASSY.
3 Main PCB failure Replace the main PCB ASSY.