App.1-10
Confidential
- Selectors 1 through 3: Redial/Pause button setting and 2nd dial tone detection
- Selectors 4 through 6: Detection of 2nd dial tone
Upon detection of the 2nd dial tone for the time length specified by these selectors, the machine
starts dialing.
This setting is effective only when the 2nd dial tone detection function is activated by selectors 1
through 3 (Setting 101, 110, or 111).
This function does not apply in those countries where no dial tone detection function is supported.
- Selector 7: No. of 2nd dial tone detection cycles
This selector sets the number of dial tone detection cycles required for starting dialing.
- Selector 8: Allowable instantaneous interrupt during reception of 2nd dial tone
This selector sets the allowable instantaneous interrupt period that should be ignored during
reception of the 2nd dial tone.
Selectors
1 2 3
0 0 0 No wait is inserted even if the Redial/Pause button is pressed.
0 0 1
If you press the Redial/Pause button during dialing, the machine will insert wait
as defined in the above table.
If the Redial/Pause button is pressed repeatedly, the machine inserts the
specified wait multiplied by the number of depressions. It applies also in hook-up
dialing.
0 1 0
0 1 1
1 0 0
1 0 1 When these selectors are set to “1, 0, 1”:
Each time you press the Redial/Pause button in dialing, the machine will wait for
the 2nd dial tone to be sent via the communications line regardless of pulse
dialing or tone dialing.
When these selectors are set to “1, 1, 0”:
If you press the Redial/Pause button in pulse dialing, the machine will first wait
for the 2nd dial tone to be sent via the communications line.
After that, pressing the Redial/Pause button will cause the machine to insert a
WAIT of 3.5 seconds. In tone dialing, the machine will insert a WAIT of 3.5
seconds.
When these selectors are set to “1, 1, 1”:
If you press the Redial/Pause button, the machine will first wait for the 2nd dial
tone to be sent via the communications line regardless of pulse dialing or tone
dialing. After that, pressing the Redial/Pause button will cause the machine to
insert a wait of 3.5 seconds.
((In those countries where no dial tone detection function is supported,
setting these selectors to “1, 0, 1,” “1, 1, 0,” or “1, 1, 1” inserts a wait of
3.5 seconds.)
1 1 0
1 1 1