Select the trigger for the setup selection.
Option Name Description
[0] Digital input A digital input triggers the setup
selection.
[1] Bus A serial communication port or the
fieldbus triggers the setup selection.
[2] Logic AND The fieldbus/serial communication port
and a digital input trigger the setup
selection.
[3] Logic OR The fieldbus/serial communication port or
a digital input triggers the setup selection.
8-56 Preset Reference Select
Default value: [3] Logic OR Parameter type: Option
Setup: All setups Conversion index: –
Data type: Uint8 Change during operation: True
Select the trigger for the preset reference selection.
Option Name Description
[0] Digital input A digital input triggers the preset
reference selection.
[1] Bus A serial communication port or the
fieldbus triggers the preset reference
selection.
[2] Logic AND The fieldbus/serial communication port
and a digital input trigger the preset
reference selection.
[3] Logic OR The fieldbus/serial communication port
or a digital input triggers the preset
reference selection.
8-57 PROFIdrive OFF2 Select
Default value: [3] Logic OR Parameter type: Option
Setup: All setups Conversion index: –
Data type: Uint8 Change during operation: True
Select control of the drive OFF2 selection via the terminals (digital input) and/or via the fieldbus. This parameter is active only when
parameter 8-01 Control Site is set to [0] Digital and ctrl. word and parameter 8-10 Control Word Profile is set to [1] PROFIdrive profile.
182 | Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507
Programming Guide | VLT® AutomationDrive FC 360