Table 21: Bits Definition (continued)
Bits Definition
Bit 5 Digital input terminal 18
Bit 10 Digital input terminal 31
16-61 Terminal 53 Setting
Default value: Size related Parameter type: Option
Setup: 1 setup Conversion index: –
Data type: Uint8 Change during operation: True
View the setting of input terminal 53.
Option Name
[0] Current mode
[1] Voltage mode
16-62 Analog input 53
Default value: 1.00 Parameter type: Range (0.00–20.00)
Setup: 1 setup Conversion index: -2
Data type: Uint16 Change during operation: True
View the actual value at input 53.
16-63 Terminal 54 Setting
Default value: Size related Parameter type: Option
Setup: 1 setup Conversion index: –
Data type: Uint8 Change during operation: True
View the setting of input terminal 54.
Option Name
[0] Current mode
[1] Voltage mode
16-64 Analog input 54
Default value: 1.00 Parameter type: Range (0.00–20.00)
Setup: 1 setup Conversion index: -2
Data type: Uint16 Change during operation: True
260 | Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507
Programming Guide | VLT® AutomationDrive FC 360

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 360 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 360 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 360
CategoryDC Drives
LanguageEnglish

Related product manuals