Programming Guide | VLT® AutomationDrive FC 360
0-14 Readout: Edit Set-ups/Channel
Default value: 0 Parameter type: Range (-2147483647–
2147483647 )
Setup: All setups Conversion index: 0
Data type: Int32 Change during operation: True
View the setting of parameter 0-11 Programming Set-up. Edit setup for each communication channel. A means active setup; F means
factory; numbers indicate setup code. Communication channels from right to left are LCP and FC-bus.
0-16 Application Selection
Default value: [0] None Parameter type: Option
Setup: All setups Conversion index: –
Data type: Uint8 Change during operation: False
Select integrated application functions. When an application is selected, a set of related parameters are set automatically.
Option Name
[0] None
[1] Simple Process Close Loop
[2] Local/Remote
[3] Speed Open Loop
[4] Simple Speed Close Loop
[5] Multi Speed
[6] OGD LA10
[7] OGD V210
[8] Hoist
[9] Hoist Speed Close Loop
[10] Horizontal Position Control
[11] Vertical Position Control
[25] Flux Hoist
[26] Flux Hoist Speed Close Loop
[27] Stacker Crane Horizontal
[28] Stacker Crane Vertical
 NOTICE
The option [25] Flux Hoist and [26] Flux Hoist Speed Close Loop are hidden without flux license activation.