CONTROLS
1001 DFB
Drilling & Sawing Line
9. Selecting switch: DESCENT of vertical hold down 1.
Active in MANUAL mode.
It enables the descent of the hold down switch stands in the sector
of the negative mitering (-) (optional).
10. Not used (optional)
11. Selector for manual ACTIVATION of the blade guide.
To move the stationary reference band guide it is necessary to
execute the zero cycle.
12. Selector for manual DESACTIVATION of the blade guide.
To move the stationary reference band guide it is necessary to
execute the zero cycle.
13. Selector to control band rotation Start/Stop.
Start: it qualifies the band rotation ( active only in MANUAL
mode and not active during band change).
Stop : disactivate and stop of band rotation.
14. Selector to qualify the sawing cycle in manual mode - (For details
refer to programming manual).
15. Selector to enable the arc descent stop downward - (For details refer
to programming manual).
16. Selector to enable the Up/down cycle- (For details refer to
programming manual).