7.3.3 Concluding steps
Ê If applicable, "Performing a RAID array rebuild" on page 81
7.4 Replacing a 2.5-inch HDD / SSD / PCIe SSD
module
V CAUTION!
● Only remove an HDD / SSD /PCIe SSD module during operation if
the drive is not currently being accessed. Observe the indicators for
the corresponding HDD / SSD modules, see operating manual of
your server.
● Under no circumstances should you remove an HDD / SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
● All HDD / SSD / PCIe SSD modules (drives) must be uniquely
identified so that they can be reinstalled in their original mounting
locations later. If this is not done, existing data can be lost.
7.4.1 Preliminary steps
Ê "Locating the defective server" on page 43
Ê Locate the defective HDD / SSD / PCIe SSD module as described in section
"Local diagnostic indicators on the front" on page 45.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools: tool-less